{"created":"2023-06-19T09:36:15.281701+00:00","id":858,"links":{},"metadata":{"_buckets":{"deposit":"8bd85219-8788-410d-942c-aca67a9541a1"},"_deposit":{"created_by":16,"id":"858","owners":[16],"pid":{"revision_id":0,"type":"depid","value":"858"},"status":"published"},"_oai":{"id":"oai:mue.repo.nii.ac.jp:00000858","sets":["1:3:88"]},"author_link":["1800","1827","1799"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-01-30","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"168","bibliographicPageStart":"165","bibliographicVolumeNumber":"54","bibliographic_titles":[{"bibliographic_title":"宮城教育大学紀要"},{"bibliographic_title":"Bulletin of Miyagi University of Education","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"By using a stable LED as a light source and a polychromator equipped with a linear image sensor, a weak absorption spectrum observation method in the visible region is proposed. This method is applied to the weak absorption spectra of pure water and benzene. The observed spectra coincide well with those in literatures over a range of absorbance down to 2×10-3.","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宮城教育大学"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"池山, 剛"}],"nameIdentifiers":[{"nameIdentifier":"1799","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"9000045454278","nameIdentifierScheme":"CiNii ID","nameIdentifierURI":"http://ci.nii.ac.jp/nrid/9000045454278"}]},{"creatorNames":[{"creatorName":"志賀, 千紘"}],"nameIdentifiers":[{"nameIdentifier":"1800","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"9000406296488","nameIdentifierScheme":"CiNii ID","nameIdentifierURI":"http://ci.nii.ac.jp/nrid/9000406296488"}]},{"creatorNames":[{"creatorName":"山形, 瑞季"}],"nameIdentifiers":[{"nameIdentifier":"1827","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"9000406296489","nameIdentifierScheme":"CiNii ID","nameIdentifierURI":"http://ci.nii.ac.jp/nrid/9000406296489"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-03-04"}],"displaytype":"detail","filename":"165-168.pdf","filesize":[{"value":"1.8 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"安定なLED 光源を利用した微弱吸収スペクトルの測定法","url":"https://mue.repo.nii.ac.jp/record/858/files/165-168.pdf"},"version_id":"9e60473c-238b-46b3-94e3-be2755aa070f"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"安定なLED 光源を利用した微弱吸収スペクトルの測定法","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"安定なLED 光源を利用した微弱吸収スペクトルの測定法"},{"subitem_title":"Observation method of weak absorption spectrum using a stable LED as a light source","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"16","path":["88"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-03-04"},"publish_date":"2020-03-04","publish_status":"0","recid":"858","relation_version_is_last":true,"title":["安定なLED 光源を利用した微弱吸収スペクトルの測定法"],"weko_creator_id":"16","weko_shared_id":-1},"updated":"2023-06-19T09:52:52.767370+00:00"}